Do I need ATC authorization here? Reading the chart for Part 107
Under § 107.41 you need prior ATC authorization to fly in Class B, Class C or Class D airspace, or within the lateral boundaries of a Class E surface area designated for an airport (the dashed magenta line). You do not need it in Class G, or in Class E that starts at 700 or 1,200 ft AGL. On the chart, the question is which boundary you are inside and whether that sector reaches down to your altitude.
Last reviewed
The excerpts are cut from FAA sectional charts, edition effective October 29, 2026, with red numbered markers (areas) added by us. Sectional charts are updated every 56 days, so every reading below describes the excerpt as printed, not the chart you would buy today.
The legend rule
No person may operate a small unmanned aircraft in Class B, Class C, or Class D airspace or within the lateral boundaries of the surface area of Class E airspace designated for an airport unless that person has prior authorization from ATC.
Source: 14 CFR 107.41 (operation in certain airspace)
Part 107 remote pilots may fly in Class G up to 400 ft AGL, and within 400 ft of a structure, without prior coordination with ATC; in most cases Class E needs no authorization either.
Source: AIM 11-4-2 (Part 107 operations in Class G and controlled airspace); Remote Pilot Study Guide ch. 2 (Class E airspace)
Authorizations are obtained through the FAA's airspace access processes, including the FAA's Low Altitude Authorization and Notification Capability (LAANC) for near real-time approval, and are not arranged by calling ATC on the radio.
Source: AIM 11-8-2 (how drone airspace authorizations are coordinated); AIM 11-4-2 (Part 107 operations in Class G and controlled airspace)
Reading the chart: solid blue sector blocks are Class B, solid magenta are Class C (both MSL); a dashed blue line is Class D; a dashed magenta line is a Class E surface area. Part-time Class D or Class E surface areas carry an effective-hours note, and when one is not in effect it becomes Class E surface or Class G, as the Chart Supplement states.
Source: Chart User's Guide, VFR terms p. 16 (right traffic; Class B and Class C altitudes); Chart User's Guide, VFR terms p. 16 (Class D boundary, ceilings and part-time note); Chart User's Guide, VFR terms p. 17 (Class E surface areas, vignettes, Class G); AIM 3-2-5 (Class D airspace; part-time surface areas)
Worked examples
Example 1: Figure 101, area 2
Area 2 sits on a thick blue Class B line. Just north of that line (above the marker) the block reads 100 over SFC; south of it, 100 over 18. Does a drone flight at 150 ft AGL in the 100 over SFC sector north of the line need ATC authorization?
Open Figure 101, area 2 full size
- The block just north of area 2 reads 100 over SFC in blue: Class B from the surface to 10,000 ft MSL. (The 100 over 18 block south of the line is a different sector, with a 1,800-ft MSL floor.)
- Because the sector starts at the surface, any drone altitude there is inside Class B.
- § 107.41: prior ATC authorization is required.
Reading: Yes. That sector is Class B down to the surface.
Source: Chart User's Guide, VFR terms p. 16 (right traffic; Class B and Class C altitudes); 14 CFR 107.41 (operation in certain airspace)
Example 2: Figure 104, area 2
Does the Class B sector at area 2 (100 over 19) apply to a drone at 400 ft AGL?
Open Figure 104, area 2 full size
- Floor 1,900 ft MSL. The obstruction just below the block, 978 (344), puts the ground near 634 ft MSL.
- A drone at 400 ft AGL is at about 1,034 ft MSL, well below the floor.
- So this Class B sector does not require authorization for that flight. Whether anything else does depends on what is drawn underneath, so check for any dashed blue or dashed magenta line at your spot.
Reading: No, not this sector: its floor is about 1,266 ft above the ground. Then check the airspace beneath it.
Source: Chart User's Guide, VFR terms p. 16 (right traffic; Class B and Class C altitudes); Chart User's Guide, VFR terms p. 11 (obstruction symbols: MSL top, AGL height in parentheses); 14 CFR 107.41 (operation in certain airspace)
Example 3: Figure 110, area 3
The Waycross airport at area 3 has no control tower (magenta). Does a drone inside the dashed magenta circle need authorization?
Open Figure 110, area 3 full size
- Magenta data block: no tower.
- The dashed magenta circle is a Class E surface area designated for the airport.
- § 107.41 names that surface area explicitly, so prior ATC authorization is required inside it, tower or not.
Reading: Yes. A Class E surface area needs authorization even at a non-towered airport.
Source: Chart User's Guide, VFR terms p. 17 (Class E surface areas, vignettes, Class G); Chart User's Guide, VFR terms p. 15 (towered airports in blue, others in magenta; lighting codes); 14 CFR 107.41 (operation in certain airspace)
Check yourself
Three options each, as on the test. Pick one, then open the answer.
-
Open Figure 108, area 2 full size
Figure 108, area 2 River city with Class C sector blocks, several Class D airports and tall obstructions. Tap to zoom. Does a drone flight at 100 ft AGL inside the sector marked 40 over SFC at area 2 need ATC authorization?
Show the answer
B. Yes: it is Class C from the surface to 4,000 ft MSL. The magenta 40 over SFC is the Class C core from the surface; § 107.41 requires authorization in Class C.
Source: Chart User's Guide, VFR terms p. 16 (right traffic; Class B and Class C altitudes); 14 CFR 107.41 (operation in certain airspace)
-
Open Figure 103, area 6 full size
Figure 103, area 6 Mountain-edge valley with a Class D airport, Class E shading, private strips, obstructions and military training routes. Tap to zoom. A remote pilot wants to fly at 300 ft AGL over the private airstrip at area 6, where no Class B, C or D boundary and no dashed magenta line is drawn. Is ATC authorization required?
Show the answer
A. No: the airspace there from the surface is Class G. With Class E starting at 700 or 1,200 ft AGL, the airspace at 300 ft AGL is Class G, where no authorization is needed. A private strip does not create controlled airspace.
Source: Chart User's Guide, VFR terms p. 17 (Class E surface areas, vignettes, Class G); Remote Pilot Study Guide ch. 2 (Class G airspace); 14 CFR 107.41 (operation in certain airspace)
-
Open Figure 104, area 5 full size
Figure 104, area 5 Lakeside metropolitan Class B with two major airports, sector blocks, a Class C core and satellite Class D airports. Tap to zoom. Is ATC authorization needed to fly at 200 ft AGL inside the dashed blue circle beside area 5?
Show the answer
A. Yes: it is Class D airspace. A dashed blue line is Class D from the surface (here to 3,300 ft MSL); § 107.41 requires authorization.
Source: Chart User's Guide, VFR terms p. 16 (Class D boundary, ceilings and part-time note); 14 CFR 107.41 (operation in certain airspace)
-
Open Figure 101, area 1 full size
Figure 101, area 1 Coastal metropolitan area with Class B sector blocks, satellite Class D airports and a seaplane base. Tap to zoom. Over the water at area 1, does the Class B sector printed there (100 over 30) apply to a drone at 400 ft AGL?
Show the answer
C. No: this sector's floor is 3,000 ft MSL, far above the drone. The sector runs from 3,000 ft MSL to 10,000 ft MSL. Over water near sea level, 400 ft AGL is far below its floor; any airspace beneath it is a separate reading.
Source: Chart User's Guide, VFR terms p. 16 (right traffic; Class B and Class C altitudes)
-
Open Figure 106, area 3 full size
Figure 106, area 3 Desert metropolitan area with Class B sector blocks, satellite Class D airports and obstructions. Tap to zoom. The North Las Vegas tower (area 3) shows a star after its frequency, and a nearby note reads See NOTAMs/Supplement for Class D/E (sfc) eff hrs. When the tower is closed, what applies to the surface area?
Show the answer
B. It becomes Class E surface or Class G, as published; check the Chart Supplement and NOTAMs. A part-time Class D surface area reverts to a Class E surface area or Class G; the Chart Supplement entry says which. If it is Class E surface, § 107.41 still applies.
Source: AIM 3-2-5 (Class D airspace; part-time surface areas); Chart User's Guide, VFR terms p. 15 (airport data: elevation, runway length, CT, star, CTAF); 14 CFR 107.41 (operation in certain airspace)
Common slips
- Thinking non-towered means no authorization. A dashed magenta Class E surface area needs it.
- Thinking anything inside the outer Class B ring needs authorization. Only the sector you are in, from its floor up, counts.
- Thinking 400 ft AGL is always legal without authorization. In Class B, C, D and surface E it is not.
- Forgetting part-time airspace. Check the effective-hours note and the Chart Supplement.
See where you stand on the whole test
Chart reading is one part of the Part 107 test. The free Muster Check covers all five test areas in the proportions the real test uses and shows the cited source for every answer.
More chart practice
- How to read Class B and Class C sector blocks
- Class D on a sectional chart: ceiling boxes and part-time towers
- Class E and Class G on a sectional: magenta vs blue shading and dashed magenta
- Obstruction heights on a sectional chart: MSL vs AGL and the 400-ft rule
- Maximum elevation figures (MEF) on a sectional chart
- Special use airspace and military training routes on a sectional chart
- How to read an airport data block on a sectional chart
Chart excerpts: FAA VFR sectional charts (public domain), markers added. Rules: FAA Aeronautical Chart User's Guide, Aeronautical Information Manual, Remote Pilot Study Guide and 14 CFR part 107. Independent study tool. Not affiliated with or endorsed by the FAA.